* After exhaustive discussion and study determine the exact requirement of the equipments for Fume Treatment Plant (FTP)
* Design and Dimension the FTP System on the basis of exhaust gas conditions at the inlet point(Furnace Hood) and at the outlet point(Stack)
* A combined FTP and De Dusting Plant for EAF(Primary) + EAF(Secondary, through Canopy) + LHF + MHS
* Complete Design/Dimensioning of Roof Elbow , Duct to Combustion chabme, Moving Sleeve, Combustion Chamber, Water Cooled Duct, Butterfly Valves(water cooled and non-cooled), Gas Cooler, Bag House , Stack.
* Design for combined Gas flow as high as 15,00,000(1.5 Million) Nm3/Hr
* Dust level as low as 15mg/Nm3 of exhaust gases at the outlet of stack
* Online Monitoring equipment for continuous dust content monitoring